Ticket #10334 (closed: fixed)

Opened 6 years ago

Last modified 5 years ago

Indirect data reduction UI causes calibration to run multiple times

Reported by: Dan Nixon Owned by: Dan Nixon
Priority: major Milestone: Release 3.3
Component: Indirect Inelastic Keywords:
Cc: Blocked By:
Blocking: Tester: Harry Jeffery

Description (last modified by Dan Nixon) (diff)

After entering a run number any interaction with the UI that does not result in the run files widget losing focus will cause the reduction algorithm to be executed even when the data has not changed.

Change History

comment:1 Changed 6 years ago by Dan Nixon

  • Status changed from new to assigned

comment:2 Changed 6 years ago by Dan Nixon

  • Description modified (diff)

comment:3 Changed 6 years ago by Dan Nixon

  • Status changed from assigned to inprogress

Only update calibration plots when the data changes

Refs #10334

Changeset: 41cac25f44dbf457b995b7d65cdc20aa7f67a8d1

comment:4 Changed 6 years ago by Dan Nixon

  • Status changed from inprogress to verify
  • Resolution set to fixed

To test:

  • Optional step: with a master build open I > DR > Calib, enter a run number of filename, once the plot has finished click on some whitespace on the UI, notice plotting and reduction is done again
  • Follow the same steps on the feature branch and notice that this does not happen
  • Change the run number and the plotting and reduction will be done for the new file

comment:5 Changed 6 years ago by Harry Jeffery

  • Status changed from verify to verifying
  • Tester set to Harry Jeffery

comment:6 Changed 6 years ago by Harry Jeffery

  • Status changed from verifying to closed

Merge remote-tracking branch 'origin/feature/10334_idr_cal_runs_preview_algorithm_multiple_times'

Full changeset: 854e8ddbd4aa3ede089ee26a79b563139ac408f1

comment:7 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 11176

Note: See TracTickets for help on using tickets.