Have all excitation instruments go to ceph and the rest somewhere else (probably for next cycle 'the archieve', i.e. on windows mounted as
isis\inst$\blah...).
Out of ISIS cycle we may not be able to write to the archieve.
For this ticket chance PostProcessAdmin so that all excitation group reduced data go to one location and all other instrument reduced data to another location.
For this ticket simply make this locations the same.
Attachments
Change History
comment:1 Changed 5 years ago by Anders Markvardsen
- Owner changed from Anders Markvardsen to Lottie Greenwood
- Status changed from new to assigned
Note now PostProcessAdmin run as users which can write to \isis\
to test do e.g.
touch /isis/NDXWISH/Instrument/data/cycle_14_3/autoreduced/test5.txt
comment:2 Changed 5 years ago by Lottie Greenwood
- Status changed from assigned to verify
- Resolution set to fixed
verified as https://github.com/mantidproject/autoreduce/pull/13
to test, log onto autoreduce server and watch the logs whilst running a WISH and LET run. WISH should state it is going to the archive, LET to CEPH.
comment:3 Changed 5 years ago by Anders Markvardsen
- Status changed from verify to verifying
- Tester set to Anders Markvardsen
comment:4 Changed 5 years ago by Anders Markvardsen
- Status changed from verifying to reopened
- Milestone changed from Release 3.4 to Release 3.5
- Resolution fixed deleted
- Description modified (diff)
- Summary changed from Enable two archieves in PostProcessAdmin to Enable PostProcessAdmin to handle two reduction data storage location
Reopen, and see change of ticket description