Ticket #1891 (closed: fixed)
Direct ConvertToEnergy GUI: Background Ranges entered in the GUI are not used.
Reported by: | Stuart Campbell | Owned by: | Martyn Gigg |
---|---|---|---|
Priority: | major | Milestone: | Iteration 26 |
Component: | Mantid | Keywords: | |
Cc: | Martyn, Gigg | Blocked By: | |
Blocking: | Tester: | Michael Whitty |
Description
On the "Energy Transfer" tab, under "Analysis Options"...
Any values entered in the GUI for TOF Start and TOF End are ignored and the values that are defined in the $INST_Parameters.xml file (i.e. bkgd-range-min and bkgd-range-max are used instead.
Change History
comment:2 Changed 10 years ago by Stuart Campbell
This is a strange one, not 100% reproducible. But if you don't run the diag command then it mostly seems to fail. More investigation needed!
comment:3 Changed 10 years ago by Nick Draper
- Status changed from new to assigned
- Owner set to Stuart Campbell
assigned to stuart while investigation ongoing
comment:4 Changed 10 years ago by Stuart Campbell
How to reproduce:
Start the ConvertToEnergy GUI, select CNCS.
Enter the following data...
Runs: /Test/Data/sns_event_prenexus/CNCS_7850_neutron_event.dat
bg removal: on (44500 to 48000)
Ei = 3
Fix Ei: True
Tzero = 61.77
Rebin:-2.0, 0.1, 2.0
No output files are needed.
Turn off the other 2 tabs
comment:7 Changed 10 years ago by Martyn Gigg
- Status changed from accepted to verify
- Resolution set to fixed
comment:8 Changed 10 years ago by Michael Whitty
- Status changed from verify to verifying
- Tester set to Michael Whitty
comment:9 Changed 10 years ago by Michael Whitty
- Status changed from verifying to closed
workspace history shows it using the user-input values.
comment:10 Changed 5 years ago by Stuart Campbell
- Cc Martyn, Gigg added; Martyn Gigg removed
This ticket has been transferred to github issue 2738