Ticket #2496 (closed: fixed)
Unwrapped instrument view doesn't work with rectangular detectors
Reported by: | Peter Peterson | Owned by: | Roman Tolchenov |
---|---|---|---|
Priority: | major | Milestone: | Iteration 28 |
Component: | Mantid | Keywords: | |
Cc: | Blocked By: | ||
Blocking: | Tester: | Andrei Savici |
Description
While it works wonderfully for CNCS and SEQUOIA, instruments that are defined with rectangular detectors in the instrument file (POWGEN, SNAP, TOPAZ) show nothing.
Change History
comment:1 Changed 9 years ago by Nick Draper
- Status changed from new to assigned
- Owner set to Roman Tolchenov
comment:4 Changed 9 years ago by Roman Tolchenov
- Status changed from accepted to verify
- Resolution set to fixed
comment:5 Changed 9 years ago by Andrei Savici
- Status changed from verify to verifying
- Tester set to Andrei Savici
Note: See
TracTickets for help on using
tickets.