Ticket #2758 (closed: fixed)

Opened 10 years ago

Last modified 5 years ago

Allow specifiacation of the other SANS transmission detector.

Reported by: Steve Williams Owned by: Steve Williams
Priority: major Milestone: Iteration 29
Component: Mantid Keywords:
Cc: Blocked By:
Blocking: Tester: Mathieu Doucet

Description

In ISIS SANS runs the transmission is calculated from the number of neutrons reaching the a post-sample monitor (normally detector ID = spectrum = 3) and the pre-sample (normaliation) monitor (normally 2).

The pre-sample monitor is specified in the user file with MON/TRANS/SPECTRUM=? and can be overriden in the monitors section of the Analysis Details tab of the SANS GUI.

Todo: The post-sample monitor will be specfied with TRANS/TRANSPEC=? in the user file and overriden by a box on the GUI similar to above. There will be documentation inhttp://www.mantidproject.org/SANS_User_File_Commands and http://www.mantidproject.org/Using_the_SANS_GUI .

Change History

comment:1 Changed 10 years ago by Steve Williams

  • Status changed from new to accepted

If not set this value is left at default-transmission-monitor-spectrum from the parameters xml file.

comment:2 Changed 10 years ago by Steve Williams

(In [10680]) The SANS user file now parses TRANS/TRANSPEC for use in the transmission calculation re #2758

comment:3 Changed 10 years ago by Steve Williams

(In [10695]) The SANS transmission calculation can be performed with any combination of monitors re #2758

comment:4 Changed 9 years ago by Steve Williams

(In [10733]) The SANS fix bug with log fit setting not making it to the GUI re #2758

comment:5 Changed 9 years ago by Steve Williams

(In [10751]) Allow the SANS full range transmission ranges to be changed re #2758

comment:6 Changed 9 years ago by Steve Williams

  • Milestone changed from Iteration 28 to Iteration 29

comment:7 Changed 9 years ago by Steve Williams

The new user commands have been set up and work as in http://www.mantidproject.org/SANS_User_File_Commands The GUI additions now have lower priority and are in ticket #3176

comment:8 Changed 9 years ago by Steve Williams

  • Status changed from accepted to verify
  • Resolution set to fixed

comment:9 Changed 9 years ago by Mathieu Doucet

  • Status changed from verify to verifying
  • Tester set to Mathieu Doucet

comment:10 Changed 9 years ago by Mathieu Doucet

  • Status changed from verifying to closed

Everything seems to be there. Checked that the monitor IDs are passed properly when calling CalculateTranmission.

comment:11 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 3605

Note: See TracTickets for help on using tickets.