Ticket #3017 (closed: fixed)

Opened 9 years ago

Last modified 5 years ago

MuonAnalysis: Load current run for ARGUS

Reported by: Anders Markvardsen Owned by: Anders Markvardsen
Priority: major Milestone: Iteration 29
Component: Mantid Keywords:
Cc: Blocked By:
Blocking: Tester: Steve Williams

Description

Francis feedback.

Trying to load DAE for Argus does not work.

Change it so that it pick up


ndw828\argusdata\current cycle\nexus

and the file argus0000000.nxs

Change History

comment:1 Changed 9 years ago by Anders Markvardsen

  • type changed from enhancement to defect

comment:2 Changed 9 years ago by Anders Markvardsen

  • Status changed from new to accepted
  • Summary changed from Does not pick up the right DAE directory for ARGUS to MuonAnalysis: Load current run for ARGUS

Looking at this more closely, then at least for ARGUS should not read from DAE but instead from the ISIS file


ndw828\argusdata\current cycle\nexus

made for this purpose.

Change MuonAnalysis to read this file.

To test:

1) On an ISIS machine open MuonAnalysis 2) Make sure Argus is selected as the instrument at the top 3) Hit the Load current run button

You should either see a plot appear or message saying that can find
ndw828\argusdata\current cycle\nexus which will appear if ndw828 is down.

comment:3 Changed 9 years ago by Anders Markvardsen

(In [11653]) Fix to re #3017

comment:4 Changed 9 years ago by Anders Markvardsen

  • Status changed from accepted to verify
  • Resolution set to fixed

comment:5 Changed 9 years ago by Steve Williams

  • Status changed from verify to verifying
  • Tester set to Steve Williams

comment:6 Changed 9 years ago by Steve Williams

  • Status changed from verifying to closed

I hit the "Load current run" button and a workspace was loaded and ploteted. It was called ARGUS0000000

comment:7 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 3864

Note: See TracTickets for help on using tickets.