Ticket #3040 (closed: fixed)

Opened 9 years ago

Last modified 5 years ago

MuonAnalysis: axis labels in plots equal those in workspaces

Reported by: Anders Markvardsen Owned by: Anders Markvardsen
Priority: minor Milestone: Iteration 29
Component: MantidPlot Keywords:
Cc: Blocked By:
Blocking: Tester: Michael Reuter

Description

When generating plots in MuonAnalysis the resulting labels in plots are different from those listed in the generated workspace, i.e. on right-hand panel in workspace for labels 'X axis' and 'Y axis'

Change History

comment:1 Changed 9 years ago by Anders Markvardsen

(In [11790]) Make ylabels in plots generated from MuonAnalysis consistent with ylabels in corresponding workspaces. re #3040

comment:2 Changed 9 years ago by Anders Markvardsen

(In [12251]) When loading Muon data change Unit from TOF to custom Label unit with label Time / microsecond. re #3040

comment:3 Changed 9 years ago by Anders Markvardsen

(In [12255]) Fix build. re #3040

comment:4 Changed 9 years ago by Anders Markvardsen

  • Status changed from new to accepted

comment:5 Changed 9 years ago by Anders Markvardsen

  • Status changed from accepted to verify
  • Resolution set to fixed

To test open any data in the MuonAnalysis custom interface. Then check that the axis labels plotted matches those listed in workspace

comment:6 Changed 9 years ago by Michael Reuter

  • Status changed from verify to verifying
  • Tester set to Michael Reuter

comment:7 Changed 9 years ago by Michael Reuter

  • Status changed from verifying to closed

This seems to be correct.

comment:8 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 3887