nxspe file format has field to store psi (the crystal rotation wrt the reference frame). This is important parameter, which is currently used by all software, accepting nxspe. (in ISIS)

save_nxspe algorithm have field to enter psi value, but when a user uses convert_to_energy interface and asks to save data as nxspe, there are no place to enter psi and default value (0) will be stored in resulting nxspe, making the data analysis incorrect, based on resulting nxspe incorrect unless this value is stored in nxspe using an hdf-editor.

The option to provide psi has to be available when user selects "save nxspe" file.

Change History

comment:1 Changed 9 years ago by Nick Draper

  • Milestone changed from Iteration 29 to Iteration 30

"New" tickets moved at the code freeze of iteration 29

comment:2 Changed 9 years ago by Nick Draper

  • Status changed from new to assigned
  • Owner set to Martyn Gigg

comment:3 Changed 9 years ago by Nick Draper

  • Priority changed from major to critical

comment:4 Changed 9 years ago by Nick Draper

  • Milestone changed from Iteration 30 to Iteration 31

Bulk move of tickets to iteration 31 at the iteration 30 code freeze

comment:5 Changed 9 years ago by Andrei Savici

Changed a keyword for saveNXSPE Refs #3208

Convert to energy transfer interface works for MARI11001.raw. Do not put anything in the SEMotor. Anything you put in offset will be stored as psi in the nxspe.

Changeset: fabd7dc9b224470af899808c8f207282aaa74dc0

comment:6 Changed 9 years ago by Andrei Savici

Changed a keyword for saveNXSPE Refs #3208

Convert to energy transfer interface works for MARI11001.raw. Do not put anything in the SEMotor. Anything you put in offset will be stored as psi in the nxspe.

Changeset: fabd7dc9b224470af899808c8f207282aaa74dc0

comment:7 Changed 9 years ago by Nick Draper

  • Milestone changed from Iteration 32 to Iteration 33

Moved to iteration 33 at iteration 32 code freeze

comment:8 Changed 8 years ago by Nick Draper

  • Milestone changed from Release 2.1 to Release 2.2

Moved at end of release 2.1

comment:9 Changed 8 years ago by Andrei Savici

  • Owner changed from Martyn Gigg to Andrei Savici

comment:10 Changed 8 years ago by Andrei Savici

  • Status changed from assigned to accepted

comment:11 Changed 8 years ago by Andrei Savici

  • Status changed from accepted to verify
  • Resolution set to fixed

comment:12 Changed 8 years ago by Michael Reuter

  • Status changed from verify to verifying
  • Tester set to Michael Reuter

comment:13 Changed 8 years ago by Michael Reuter

  • Status changed from verifying to closed

The value entered into the offset entry box does appear in the psi field in the NXSPE.