Ticket #3350 (closed: fixed)

Opened 9 years ago

Last modified 5 years ago

EQSANS: fix problem with dark current

Reported by: Mathieu Doucet Owned by: Mathieu Doucet
Priority: major Milestone: Iteration 30
Component: Mantid Keywords:
Cc: Blocked By:
Blocking: Tester: Martyn Gigg

Description

The reduction fails when a dark current is set for the direct transmission determination. That is because the HFIR dark current subtraction method is called instead of pulling the appropriate class from the reducer.

Change History

comment:1 Changed 9 years ago by Mathieu Doucet

In [13161]:

Fix dark current problem and clean up. Re #3350

comment:2 Changed 9 years ago by Mathieu Doucet

In [13162]:

typo. Re #3350

comment:3 Changed 9 years ago by Mathieu Doucet

  • Status changed from new to accepted

comment:4 Changed 9 years ago by Mathieu Doucet

  • Status changed from accepted to verify
  • Resolution set to fixed

comment:5 Changed 9 years ago by Martyn Gigg

  • Status changed from verify to verifying
  • Tester set to Martyn Gigg

comment:6 Changed 9 years ago by Martyn Gigg

  • Status changed from verifying to closed

System test works and also verified that the reduction completes from the GUI and a script generated from that.

comment:7 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 4197