Ticket #3650 (closed: fixed)
HFIR SANS: fix bug with beam center within a loop
| Reported by: | Mathieu Doucet | Owned by: | Mathieu Doucet |
|---|---|---|---|
| Priority: | major | Milestone: | Iteration 30 |
| Component: | Mantid | Keywords: | |
| Cc: | Blocked By: | ||
| Blocking: | Tester: | Martyn Gigg |
Description
The following script gives a different beam center every second iteration. To test, run it and see that the same coordinates are printed for each iteration.
# HFIR reduction script
# Script automatically generated on Wed Aug 31 15:13:38 2011
from MantidFramework import *
mtd.initialise(False)
from reduction.instruments.sans.hfir_command_interface import *
BIOSANS()
DataPath("somewhere_with_data")
NoSensitivityCorrection()
SetWavelength(12,.1)
SetSampleDetectorOffset(837.9)
NoSolidAngle()
NoNormalization()
AzimuthalAverage(n_bins=100, n_subpix=1, log_binning=False)
DirectBeamCenter("some_biosans_data_file.xml")
for i in range(4):
ReductionSingleton()._data_files = {}
AppendDataFile(["some_biosans_data_file.xml"])
SaveIqAscii()
Reduce1D()
print ReductionSingleton().get_beam_center()
Change History
comment:1 Changed 9 years ago by Mathieu Doucet
- Owner set to Mathieu Doucet
- Status changed from new to accepted
comment:2 Changed 9 years ago by Mathieu Doucet
- Status changed from accepted to verify
- Resolution set to fixed
In [14351]:
comment:3 Changed 9 years ago by Robert Whitley
- Status changed from verify to verifying
- Tester set to Robert Whitley
comment:4 Changed 9 years ago by Robert Whitley
- Status changed from verifying to verify
- Tester Robert Whitley deleted
comment:5 Changed 9 years ago by Martyn Gigg
- Status changed from verify to verifying
- Tester set to Martyn Gigg
Note: See
TracTickets for help on using
tickets.