Ticket #3969 (closed: fixed)

Opened 9 years ago

Last modified 5 years ago

PredictPeaks: row and col of peaks are not accurate

Reported by: Vickie Lynch Owned by: Vickie Lynch
Priority: major Milestone: Release 2.0
Component: Mantid Keywords:
Cc: Blocked By:
Blocking: Tester: Janik Zikovsky

Description

The instrument view shows center of peaks that are as much as 13 pixels away from the row and column in PeaksWorkspace. Also TOPAZ data cannot be refined after I started using the peaks from PredictPeaks instead of ISAW.

Change History

comment:1 Changed 9 years ago by Vickie Lynch

  • Status changed from new to accepted

comment:2 Changed 9 years ago by Vickie Lynch

In [15308]:

Refs #3969 h or k or l can be 0

comment:3 Changed 9 years ago by Vickie Lynch

In [15313]:

Refs #3969 hkl are integer

comment:4 Changed 9 years ago by Vickie Lynch

In [15320]:

Refs #3969 PredictPeaks get correct detector pixel if DetCal file is used

comment:5 Changed 9 years ago by Vickie Lynch

  • Status changed from accepted to verify
  • Resolution set to fixed

comment:6 Changed 9 years ago by Janik Zikovsky

  • Status changed from verify to verifying
  • Tester set to Janik Zikovsky

comment:7 Changed 9 years ago by Janik Zikovsky

  • Status changed from verifying to closed

comment:8 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 4816