Ticket #4285 (closed: fixed)

Opened 9 years ago

Last modified 5 years ago

PeakIntegration and IntegratePeakTimeSlices for instruments with no rectangular detectors

Reported by: Vickie Lynch Owned by: Vickie Lynch
Priority: major Milestone: Release 2.0
Component: Mantid Keywords:
Cc: Blocked By:
Blocking: Tester: Wenduo Zhou

Description

PeakIntegration and IntegratePeakTimeSlices should fail gracefully if you try to point then at another type of instrument, i.e. one without rectangular detectors. The error message should be more informative that what we have at present: PeakIntegration started. Error in execution of algorithm PeakIntegration: MatrixWorkspace::getDetectorIDToWorkspaceIndexMap(): more than 1 detector for one histogram! I cannot generate a map of detector ID to workspace index.

Change History

comment:1 Changed 9 years ago by Vickie Lynch

Refs #4285 check for non-RectangularDetectors

Changeset: 822b477cc57360b2f11b9df70fa5099f464c5fd7

comment:2 Changed 9 years ago by Vickie Lynch

  • Status changed from new to accepted

comment:3 Changed 9 years ago by Vickie Lynch

  • Status changed from accepted to verify
  • Resolution set to fixed

comment:4 Changed 9 years ago by Wenduo Zhou

  • Status changed from verify to verifying
  • Tester set to Wenduo Zhou

comment:5 Changed 9 years ago by Wenduo Zhou

  • Status changed from verifying to closed

comment:6 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 5132

Note: See TracTickets for help on using tickets.