Ticket #4403 (closed: fixed)

Opened 9 years ago

Last modified 5 years ago

SANS: For SANS2D move both rear and front det

Reported by: Anders Markvardsen Owned by: Anders Markvardsen
Priority: critical Milestone: Release 2.0
Component: MantidPlot Keywords:
Cc: Blocked By:
Blocking: Tester: Michael Reuter

Description

Currently either front or rear are moved but not both despite the user file have containing instructions for both, e.g.

DET/CORR REAR X -16.0 DET/CORR REAR Z 58.0 DET/CORR FRONT X -44.0 DET/CORR FRONT Y -20.0 DET/CORR FRONT Z 47.0 DET/CORR FRONT ROT 0.0

Ensure that all these user file instructions are executed

Attachments

MASKSANS2D_112ii_6m_commissioning_M1_M4.txt (1.8 KB) - added by Anders Markvardsen 9 years ago.
mask file
directM1_9672_6m_08Aug11.DAT (8.0 KB) - added by Anders Markvardsen 9 years ago.

Change History

comment:1 Changed 9 years ago by Anders Markvardsen

Few more comments to this commit. Re #4403

Changeset: b33fe49b9f11de092d27d541dbe198606b470732

comment:2 Changed 9 years ago by Anders Markvardsen

  • Status changed from new to accepted

Changed 9 years ago by Anders Markvardsen

mask file

Changed 9 years ago by Anders Markvardsen

comment:3 Changed 9 years ago by Anders Markvardsen

  • Status changed from accepted to verify
  • Resolution set to fixed

To test:

1) dump attached files into folder

2) Open ISIS SANS GUI

3) Load mask file

4) load e.g. SANS2D dataset SANS2D00001672

5) Look at history and both rear and front detectors are moved

comment:4 Changed 9 years ago by Michael Reuter

  • Status changed from verify to verifying
  • Tester set to Michael Reuter

comment:5 Changed 9 years ago by Michael Reuter

  • Status changed from verifying to closed

Following the above prescription, I see that both the front and rear detectors have been moved.

comment:6 Changed 5 years ago by Stuart Campbell