Ticket #4854 (closed: fixed)
MUON: Add run number to run information and change the way counts are displayed.
Reported by: | Robert Whitley | Owned by: | Robert Whitley |
---|---|---|---|
Priority: | major | Milestone: | Release 2.1 |
Component: | Mantid | Keywords: | |
Cc: | anders.markvardsen@… | Blocked By: | |
Blocking: | Tester: | Anders Markvardsen |
Description
Run Number should be displayed (without leading zeros).
Counts should be converted and displayed in Mev (/1e6).
Example:
Original...
Counts: 1.22041e+08 Convert to MeV... Counts: 1.22041e+02 Mev
Display in easier to read format...
Counts: 122.041
Change History
comment:2 Changed 9 years ago by Robert Whitley
Refs #4854. Add run number and display counts in MeV for run info.
Changeset: d5601cfc45e58aa4c40c676039d6e6fc6f1bb0bc
comment:3 Changed 9 years ago by Robert Whitley
- Status changed from accepted to verify
- Resolution set to fixed
comment:4 Changed 8 years ago by Anders Markvardsen
- Status changed from verify to verifying
- Tester set to Anders Markvardsen
comment:5 Changed 8 years ago by Anders Markvardsen
- Status changed from verifying to closed
An output is now e.g.:
Run: 15190 Title: CaCO3 T=290 F=1360 Comment: 18.95MHz 100W Start: 2007-11-27T17:12:30 End: 2007-11-27T17:14:10 Counts: 0.618129000000 MeV Average Temperature: Errror - Not set in data file.