Ticket #5702 (closed: invalid)

Opened 8 years ago

Last modified 5 years ago

Plot window sizes not remembered correctly when saving projects.

Reported by: Peter Parker Owned by: Harry Jeffery
Priority: major Milestone: Release 3.3
Component: Framework Keywords:
Cc: Blocked By: #9970
Blocking: Tester: Dan Nixon

Description (last modified by Nick Draper) (diff)

This bug was highlighted while testing #4483. To reproduce:

  • Load a file and plot a spectrum.
  • Resize the plot window to something noticeable like 600 x 100 and then save the project.
  • Restart Mantid and open up the project. The plot window will be visible, but will have been resized to 526 x 468. The graph itself will still be stretched to a 6:1 ratio, and so wont be completely visible.

Change History

comment:1 Changed 8 years ago by Nick Draper

  • Milestone changed from Release 2.3 to Release 2.4

Moved to milestone 2.4

comment:2 Changed 8 years ago by Nick Draper

  • Owner set to Anyone
  • Status changed from new to assigned

comment:3 Changed 8 years ago by Nick Draper

  • Milestone changed from Release 2.4 to Release 2.5

Moved at the code freeze for release 2.4

comment:4 Changed 7 years ago by Nick Draper

  • Milestone changed from Release 2.5 to Release 2.6

Moved to r2.6 at the end of r2.5

comment:5 Changed 7 years ago by Nick Draper

  • Status changed from assigned to new

comment:6 Changed 7 years ago by Nick Draper

  • Component changed from Mantid to Framework

comment:7 Changed 7 years ago by Nick Draper

  • Milestone changed from Release 2.6 to Backlog

Moved to backlog at the code freeze for R2.6

comment:8 Changed 7 years ago by Nick Draper

  • Status changed from new to assigned

Bulk move to assigned at the introduction of the triage step

comment:9 Changed 6 years ago by Nick Draper

  • Owner changed from Anyone to Harry Jeffery
  • Description modified (diff)

comment:10 Changed 6 years ago by Nick Draper

  • Milestone changed from Backlog to Release 3.3

comment:11 Changed 6 years ago by Harry Jeffery

  • Blocked By 9970 added

comment:12 Changed 6 years ago by Harry Jeffery

  • Status changed from assigned to verify
  • Resolution set to fixed

This has been resolved as part of #9970.

Testing

  • Open a workspace
  • Plot it twice.
    • Make one of the plots tall and thin, the other short and wide
  • Save the project
  • Restart mantid / start a new project
  • Open the project you saved
  • The plots should be loaded correctly

comment:13 Changed 6 years ago by Harry Jeffery

  • Status changed from verify to reopened
  • Resolution fixed deleted

comment:14 Changed 6 years ago by Harry Jeffery

  • Status changed from reopened to verify
  • Resolution set to invalid

comment:15 Changed 6 years ago by Dan Nixon

  • Status changed from verify to verifying
  • Tester set to Dan Nixon

comment:16 Changed 6 years ago by Dan Nixon

  • Status changed from verifying to closed

comment:17 Changed 6 years ago by Dan Nixon

I noticed this strange issue just after passing this, not sure how related it is. #10679

comment:18 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 6548