Ticket #6448 (closed: worksforme)

Opened 8 years ago

Last modified 5 years ago

MERLIN tube defined by <locations> element won't show DAT file calibration

Reported by: Karl Palmen Owned by: Anders Markvardsen
Priority: critical Milestone: Release 3.0
Component: Direct Inelastic Keywords: Maintenance
Cc: anders.markvardsen@… Blocked By:
Blocking: Tester: Nick Draper

Description

If the standard-tube in the MERLIN IDF file is defined using the locations element as in the attached IDF file. The tubes in the 2D view are no longer calibrated by the DAT file as before. It looks like extra work would be needed to restore this feature.

Attachments

MERLIN_Definition_ls.xml (84.9 KB) - added by Karl Palmen 8 years ago.
MERLIN1.PNG (228.4 KB) - added by Anders Markvardsen 7 years ago.

Change History

Changed 8 years ago by Karl Palmen

comment:1 Changed 8 years ago by Karl Palmen

  • Cc anders.markvardsen@… added

comment:2 Changed 7 years ago by Nick Draper

  • Milestone changed from Release 2.5 to Release 2.6

Moved to r2.6 at the end of r2.5

comment:3 Changed 7 years ago by Nick Draper

  • Priority changed from major to critical
  • Keywords Maintenance added
  • Status changed from new to assigned
  • type changed from enhancement to defect
  • Owner set to Anders Markvardsen

Anders, Roman will be busy in this maintenance period, could you take a look at this.

comment:4 Changed 7 years ago by Nick Draper

  • Status changed from assigned to new

comment:5 Changed 7 years ago by Nick Draper

  • Component changed from Mantid to Framework

comment:6 Changed 7 years ago by Nick Draper

  • Milestone changed from Release 2.6 to Backlog

Moved to the Backlog after R2.6

comment:7 Changed 7 years ago by Anders Markvardsen

  • Milestone changed from Backlog to Release 3.0

comment:8 Changed 7 years ago by Anders Markvardsen

Karl can you double check that this problem is still valid

comment:9 Changed 7 years ago by Anders Markvardsen

  • Status changed from new to verify
  • Resolution set to worksforme

Done the following steps:

  1. Loaded MER12024 (found in cycle_11_5)
  1. displayed instrument (see attached MERLIN1.png)

where it displays as if calibrated

then repleated the above but replacing MERLIN_Definition.xml with the attached MERLIN_Definition_ls.xml and I see exactly the same in instrument, i.e. that shown in attached MERLIN1.png

Last edited 7 years ago by Anders Markvardsen (previous) (diff)

Changed 7 years ago by Anders Markvardsen

comment:10 Changed 7 years ago by Anders Markvardsen

To tester: follow the steps in comment9 and if see the same then pass

comment:11 Changed 7 years ago by Nick Draper

  • Status changed from verify to verifying
  • Tester set to Nick Draper

comment:12 Changed 7 years ago by Nick Draper

  • Status changed from verifying to closed

ok

comment:13 Changed 7 years ago by Nick Draper

  • Component changed from Framework to Direct Inelastic

comment:14 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 7294