comment:2 Changed 7 years ago by Roman Tolchenov
To tester:
- Open IDA Conv Fit tab. Use the attached files (_red for File, _res for Resolution).
- Select "Two Lorentzians" in Fit type.
- Checkbox Tie Centres must show up.
- Leave the checkbox unchecked.
- Set initial values for the Lorentzians: 1) Ampl: 1.0, Centre: 0, HWHM: 0.01; 2) Ampl: 1.0, Centre: 1.4, HWHM: 0.4
- Select Plot Output
- Click Run
- The fit must be good for both peaks (the big at 0 and the small at 1.4)
When Tie Centres is checked after clicking Run the Lorentzians' centres must be equal, goodness of the fit is unimportant.
When Fit type changes to Zero or One Lorentzian Tie Centres disappears.
comment:3 Changed 7 years ago by Roman Tolchenov
- Status changed from inprogress to verify
- Resolution set to fixed
comment:4 Changed 7 years ago by Karl Palmen
- Status changed from verify to verifying
- Tester set to Karl Palmen
comment:5 Changed 7 years ago by Karl Palmen
- Status changed from verifying to closed
- Description modified (diff)
comment:6 Changed 7 years ago by Karl Palmen
Merge remote-tracking branch 'origin/feature/7927_conv_fit_tie_checkbox'
Note: See
TracTickets for help on using
tickets.
Added a checkbox for tying lorentzian centres. Re #7927