Ticket #8676 (closed: fixed)

Opened 7 years ago

Last modified 5 years ago

LoadEventPreNexus is unable to load files from 4th pre-processor

Reported by: Wenduo Zhou Owned by: Wenduo Zhou
Priority: major Milestone: Release 3.1
Component: Framework Keywords:
Cc: Blocked By:
Blocking: Tester: Peter Peterson

Description

Vulcan has preNexus data recorded as the 4th preprocessor. The files end with neutron4.dat and pulseid4.dat. LoadEventPreNexus is not able to load these files but give out exception due to lack of instrument information.

Change History

comment:1 Changed 7 years ago by Wenduo Zhou

  • Status changed from new to inprogress

Added neutron4 puliseid4 to ext list. Refs #8676.

Changeset: 7610d5e442be777fc2479db6961b66efe5047fb3

comment:2 Changed 7 years ago by Wenduo Zhou

For testers

  1. Get to SNS/VULCAN/IPTS-7727/0/20002/preNexus/, there are VULCAN_20002_neutron4_event.dat and VULCAN_20002_pulseid4.dat.
  2. Use LoadEventPreNexus to load these 2 files explicitly. Before, there would be an exception about no instrument found. Now the file should be loaded though there is no neutron event in the output workspace. It is because that the 4th pre-processor of VULCAN is for load frame and this run did not use it.

comment:3 Changed 7 years ago by Wenduo Zhou

  • Status changed from inprogress to verify
  • Resolution set to fixed

comment:4 Changed 7 years ago by Peter Peterson

  • Status changed from verify to verifying
  • Tester set to Peter Peterson

comment:5 Changed 7 years ago by Peter Peterson

  • Status changed from verifying to closed

Merge remote branch 'origin/feature/8676_loadprenexus_4dat'

Full changeset: 15c7c3040b806cc3a3ef29f5910be3af6d0d28aa

comment:6 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 9520

Note: See TracTickets for help on using tickets.