Ticket #9699 (closed: fixed)
Add support for TFXA and TOSCA-1
Reported by: | Samuel Jackson | Owned by: | Dan Nixon |
---|---|---|---|
Priority: | major | Milestone: | Release 3.3 |
Component: | Indirect Inelastic | Keywords: | |
Cc: | Blocked By: | #9960 | |
Blocking: | #10512 | Tester: | Harry Jeffery |
Description (last modified by Samuel Jackson) (diff)
These are both older incarnations of TOSCA. We need to create appropriate IDFs and IPFs from the supplied calibration parameters and in consultation with the TOSCA instrument scientists.
As these are older versions of TOSCA, we can just define earlier versions of the TOSCA IDF with the correct date. In Stewart's words:
- For TFXA only runs >1000 are analysable
- TOSCA-1 was used for runs TSC00001 to TSC02134
People to talk to about this are Anders and Stewart Parker.
Attachments
Change History
comment:4 Changed 6 years ago by Samuel Jackson
I've added two "proof of concept" files for TFXA. These will need to be modified as the positions of the detectors are not defined accurately in 3D space, but these definitions should be enough to work for data analysis purposes, using the calibration parameters defined in the attached spreadsheet. The actual positions of the each of the detectors in 3D space for TFXA and TOSCA-1 will need to be gathered from TOSCA instrument scientists.
Changed 6 years ago by Samuel Jackson
- Attachment TFXA_&_TOSCA1_Calibration_params.xls added
Parameters for TFXA and TOSCA-1
comment:6 Changed 6 years ago by Dan Nixon
- Status changed from assigned to inprogress
Work in progress: Added new IDF and IPFs for TFXA and TOSCA-1
Refs #9699
Changeset: 3275ec50746cd7b72f541748ae8d9f46748cd42c
comment:7 Changed 6 years ago by Dan Nixon
Tidy up XML, correct TOSCA/-1 operation dates, add det data
Refs #9699
Changeset: 291cea54445683ef093cc9b43814eb7133cf11ba
comment:8 Changed 6 years ago by Dan Nixon
Merge branch 'master' into feature/9699_support_tfxa_and_tosca1
Conflicts:
Code/Mantid/instrument/TOSCA_Definition.xml
Refs #9699
Changeset: 473365ad97c0580478158db083e0c47aeeeec258
comment:10 Changed 6 years ago by Dan Nixon
Merge branch 'master' into feature/9699_support_tfxa_and_tosca1
Refs #9699
Changeset: 7fc5b6a80cbd2f2ed209963a74b3cf8e51d6e842
comment:11 Changed 6 years ago by Dan Nixon
comment:12 Changed 6 years ago by Dan Nixon
comment:13 Changed 6 years ago by Dan Nixon
Remove default rebinning, correct monitor numbers
Refs #9699
Changeset: c1f53b4b16a43134502c4be2c491c56e80bf1d59
comment:14 Changed 6 years ago by Dan Nixon
comment:15 Changed 6 years ago by Dan Nixon
comment:16 Changed 6 years ago by Dan Nixon
comment:17 Changed 6 years ago by Dan Nixon
Added additional parameter file for TFXA
Refs #9699
Changeset: c5e9132488108c73a6aaa63d3e1ab81e0a44f3d0
comment:18 Changed 6 years ago by Dan Nixon
Use the correct monitor spectra
Added a note on the indirect instument IPF as the parameter for the monitor is very misleading.
Refs #9699
Changeset: 43a747e59e405cb2e8a9d1794432de94908200e4
comment:19 Changed 6 years ago by Dan Nixon
Support default grouping all spectra for TFXA
Refs #9699
Changeset: 7e5a1881cd405e44c37e1eae5bb8dd9cded0c11e
comment:20 Changed 6 years ago by Dan Nixon
Correct overlapping IDF dates for TOSCAs
Refs #9699
Changeset: cb034ac904d93de4f2b21b0ba445f07a9ba4535a
comment:21 Changed 6 years ago by Dan Nixon
comment:22 Changed 6 years ago by Dan Nixon
comment:23 Changed 6 years ago by Dan Nixon
Add component for what I assume is a transmission monitor
Refs #9699
Changeset: dc0fd691db8934896c32081da1f4c235abfab229
comment:25 Changed 6 years ago by Dan Nixon
Add transmission monitors to TFXA defs
Refs #9699
Changeset: 44e1507bc64dcefc0bbad12dc0b553fce22ad1c6
comment:26 Changed 6 years ago by Dan Nixon
comment:27 Changed 6 years ago by Dan Nixon
comment:28 Changed 6 years ago by Dan Nixon
comment:29 Changed 6 years ago by Dan Nixon
comment:30 Changed 6 years ago by Dan Nixon
comment:31 Changed 6 years ago by Dan Nixon
Correct monitor positions on later TFXA
Refs #9699
Changeset: 9fee572b4f28cb8192830af723167c47ca699cf8
comment:32 Changed 6 years ago by Dan Nixon
To test:
- See that the TOSCA system test is not broken.
- Reduce each of the following using the default values on the Indirect > Data Reduction > Energy Transfer UI:
- TOSCA (e.g. run 9000)
- TOSCA "DAE" (e.g. run 3000)
- TOSCA-1 (e.g. run 2000)
- TFXA (e.g. run 2000)
- TFXA /w diff detectors (e.g. run 4000)
For all except TOSCA and TOSCA DAE the output should be a single spectra with a single peak around 0 meV, zooming in to just after the peak will show some features from the sample, the plot should usually reach at least 1000 meV.
(optional) Repeat outputting in wave number.
Note this ticket is for Energy Transfer only, diffraction for TFXA is not supported.
comment:33 Changed 6 years ago by Dan Nixon
- Status changed from inprogress to verify
- Resolution set to fixed
comment:34 Changed 6 years ago by Harry Jeffery
- Status changed from verify to verifying
- Tester set to Harry Jeffery
comment:35 Changed 6 years ago by Dan Nixon
- Status changed from verifying to closed
Merge branch 'master' into feature/9699_support_tfxa_and_tosca1
Conflicts:
Code/Mantid/instrument/TOSCA_Definition.xml
Refs #9699
Full changeset: 473365ad97c0580478158db083e0c47aeeeec258
comment:36 Changed 6 years ago by Dan Nixon
Merge branch 'master' into feature/9699_support_tfxa_and_tosca1
Refs #9699
Full changeset: 7fc5b6a80cbd2f2ed209963a74b3cf8e51d6e842
comment:37 Changed 6 years ago by Harry Jeffery
Merge remote-tracking branch 'origin/feature/9699_support_tfxa_and_tosca1'
Full changeset: a8378509eea453088402f495614d33f27a6d5e89
comment:38 Changed 5 years ago by Stuart Campbell
This ticket has been transferred to github issue 10541