Ticket #10334 (closed: fixed)
Indirect data reduction UI causes calibration to run multiple times
Reported by: | Dan Nixon | Owned by: | Dan Nixon |
---|---|---|---|
Priority: | major | Milestone: | Release 3.3 |
Component: | Indirect Inelastic | Keywords: | |
Cc: | Blocked By: | ||
Blocking: | Tester: | Harry Jeffery |
Description (last modified by Dan Nixon) (diff)
After entering a run number any interaction with the UI that does not result in the run files widget losing focus will cause the reduction algorithm to be executed even when the data has not changed.
Change History
comment:3 Changed 6 years ago by Dan Nixon
- Status changed from assigned to inprogress
Only update calibration plots when the data changes
Refs #10334
Changeset: 41cac25f44dbf457b995b7d65cdc20aa7f67a8d1
comment:4 Changed 6 years ago by Dan Nixon
- Status changed from inprogress to verify
- Resolution set to fixed
To test:
- Optional step: with a master build open I > DR > Calib, enter a run number of filename, once the plot has finished click on some whitespace on the UI, notice plotting and reduction is done again
- Follow the same steps on the feature branch and notice that this does not happen
- Change the run number and the plotting and reduction will be done for the new file
comment:5 Changed 6 years ago by Harry Jeffery
- Status changed from verify to verifying
- Tester set to Harry Jeffery
comment:6 Changed 6 years ago by Harry Jeffery
- Status changed from verifying to closed
Merge remote-tracking branch 'origin/feature/10334_idr_cal_runs_preview_algorithm_multiple_times'
Full changeset: 854e8ddbd4aa3ede089ee26a79b563139ac408f1