Ticket #1725 (closed: fixed)

Opened 10 years ago

Last modified 5 years ago

Append Muon specific workspace output params when exe LoadMuonNexus

Reported by: Anders Markvardsen Owned by: Anders Markvardsen
Priority: major Milestone: Iteration 25
Component: Mantid Keywords:
Cc: Blocked By:
Blocking: Tester: Michael Reuter

Description

For example when LoadMuonNexus is called add to the workspace the following output parameter:

name=MainFieldDirection type=string default=transverse (options available transverse or longitudinal)

Change History

comment:1 Changed 10 years ago by Anders Markvardsen

(In [6899]) Appended three additional output properties to LoadMuonNexus: MainFieldDirection, TimeZero and FirstGoodData. Fixed lexical cast error when trying to read muon-transverse-data with help from Roman. Added transverse dataset. re #1725

comment:2 Changed 10 years ago by Anders Markvardsen

  • Status changed from new to accepted

comment:3 Changed 10 years ago by Anders Markvardsen

  • Status changed from accepted to verify
  • Resolution set to fixed

and updated wiki

comment:4 Changed 10 years ago by Michael Reuter

  • Status changed from verify to verifying
  • Tester set to Michael Reuter

comment:5 Changed 10 years ago by Michael Reuter

  • Status changed from verifying to closed

The code looks like it performs the requested operations. Checked by hand the calculations in the code to values in the unit. Everything looks good.

comment:6 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 2572