Ticket #1735 (closed: fixed)
Object: remove unused temperature, density, etc. fields
Reported by: | Janik Zikovsky | Owned by: | Martyn Gigg |
---|---|---|---|
Priority: | major | Milestone: | Iteration 25 |
Component: | Mantid | Keywords: | |
Cc: | Blocked By: | ||
Blocking: | Tester: | Janik Zikovsky |
Description
Change History
comment:1 Changed 10 years ago by Janik Zikovsky
- Status changed from new to assigned
- Owner changed from Janik Zikovsky to Martyn Gigg
comment:4 Changed 10 years ago by Janik Zikovsky
Hi Martyn,
Your last change broke some of the behaviour of the Instrument 3D view for RectangularDetectors. To reproduce:
- LoadEmptyInstrument with the SNAP_Definition.xml file.
- Show Instrument menu. You notice that only one sphere is shown (the sample I think) because the bounding box is ~ null in size.
- Click on any rectangular detector E1 E2 etc. in the view and nothing is shown. This all used to work and the RectangularDetector bounding boxes returned correctly as of yesterday.
comment:5 Changed 10 years ago by Martyn Gigg
- Status changed from accepted to verify
- Resolution set to fixed
comment:6 Changed 10 years ago by Janik Zikovsky
- Status changed from verify to verifying
- Tester set to Janik Zikovsky
Note: See
TracTickets for help on using
tickets.