Ticket #2792 (closed: fixed)

Opened 10 years ago

Last modified 5 years ago

Geometry tab of SANS GUI must not crop numbers from the left

Reported by: Steve Williams Owned by: Steve Williams
Priority: major Milestone: Iteration 28
Component: MantidPlot Keywords:
Cc: Blocked By:
Blocking: Tester: Michael Whitty

Description

In the Geometry tab of the SANS GUI, in the box 'SANS2D geometry (mm)' the X & Z distances of the detectors being read from the .nxs files or from the log files for .raw files are missing the most signifient figure when the number is long.

The numbers must be left justified so that only the least signifient digits are missing. The whole group box should be resizable

Change History

comment:1 Changed 9 years ago by Steve Williams

  • Status changed from new to verify
  • Resolution set to fixed

(In [11093]) The geometry section of the SANS Geometry tab now resizes with resizing the form. Where numbers are truncated this from the right, lest significant figures fixes #2792

comment:2 Changed 9 years ago by Michael Whitty

  • Status changed from verify to verifying
  • Tester set to Michael Whitty

comment:3 Changed 9 years ago by Michael Whitty

  • Status changed from verifying to closed

comment:4 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 3639

Note: See TracTickets for help on using tickets.