Ticket #2811 (closed: fixed)
Create geometry file for VISION
Reported by: | Stuart Campbell | Owned by: | Stuart Campbell |
---|---|---|---|
Priority: | critical | Milestone: | Release 2.1 |
Component: | Mantid | Keywords: | |
Cc: | Blocked By: | ||
Blocking: | Tester: | Michael Reuter |
Description
Change History
comment:3 Changed 9 years ago by Nick Draper
- Milestone changed from Iteration 29 to Iteration 30
Accepted and assigned tickets moved at iteration 29 code freeze
comment:6 Changed 9 years ago by Nick Draper
- Milestone changed from Iteration 30 to Iteration 31
Bulk move of tickets to iteration 31 at the iteration 30 code freeze
comment:7 Changed 9 years ago by Nick Draper
- Milestone changed from Iteration 32 to Iteration 33
Moved to iteration 33 at iteration 32 code freeze
comment:8 Changed 9 years ago by Stuart Campbell
- Status changed from assigned to accepted
- Priority changed from minor to critical
- type changed from enhancement to task
comment:9 Changed 9 years ago by Stuart Campbell
Initial version of VISION IDF. refs #2811
This version includes the diffraction detectors in the correct position (to the information I have at the moment)
The inelastic detectors are (almost) in their correct physical positions. They need rotating so that the tubes axis are pointing towards the sample position.
Changeset: a2746a1ab5dd8909b2680b1046de9758cedd7b30
comment:10 Changed 9 years ago by Stuart Campbell
Updated VISION geometry. refs #2811
Inelastic tubes now orientated correctly.
Changeset: 67b7c8ca6ff64b4c475ab53c219b455d7f0a31bd
comment:11 Changed 9 years ago by Stuart Campbell
Initial version of VISION IDF. refs #2811
This version includes the diffraction detectors in the correct position (to the information I have at the moment)
The inelastic detectors are (almost) in their correct physical positions. They need rotating so that the tubes axis are pointing towards the sample position.
Changeset: a2746a1ab5dd8909b2680b1046de9758cedd7b30
comment:12 Changed 9 years ago by Stuart Campbell
Updated VISION geometry. refs #2811
Inelastic tubes now orientated correctly.
Changeset: 67b7c8ca6ff64b4c475ab53c219b455d7f0a31bd
comment:13 Changed 9 years ago by Stuart Campbell
Refs #2811. Corrected X-axis direction.
I had the x-axis pointed in the opposite direction. The views now match the ISAW views of the NeXus files.
Changeset: 300e18b6d6539084df71e733683ccc9af7943dd5
comment:14 Changed 9 years ago by Stuart Campbell
Refs #2811. Corrected X-axis direction.
I had the x-axis pointed in the opposite direction. The views now match the ISAW views of the NeXus files.
Changeset: 300e18b6d6539084df71e733683ccc9af7943dd5
comment:15 Changed 9 years ago by Stuart Campbell
Updated geometry with neutronic positions. refs #2811
Using a single point for neutronic position for the whole bank. Using a single value for the Efixed for each bank.
Changeset: b3ecee8a4873d3c1c4e7ea967e1ccaee0216b360
comment:16 Changed 9 years ago by Stuart Campbell
Initial versions of VISION parameter files. refs #2811
There are some issues with the parameters in these files that will need addressing (e.g. assumes detectors numbers are sequential with no gaps)
Changeset: 983d567b40f614ad1f635bbc208acecf282ecdfe
comment:17 Changed 9 years ago by Stuart Campbell
Added category to VISION. refs #2811
So it will be listed in the various indirect guis.
Changeset: 8088503a1be5d2ed1ada8a88b2193cc3df8d6f7e
comment:18 Changed 9 years ago by Stuart Campbell
Updated VISION IDF. refs #2811
Added neutronic positions for diffraction detectors.
- This is done by adding the same position offset for the tube and pixel to the low level objects (tube / 8-pack)
Rotated inelastic banks to have the correct orientation.
Changeset: c4628e3d918f6f936651907130ce28f6ef89a589
comment:19 Changed 9 years ago by Stuart Campbell
Corrected detector angles. refs #2811
The equitorial detectors where rotated by 180 degrees. Banks 13 and 14 were off by 10 degrees.
Changeset: 336808fb808489cce9ccd631baae8351687c1dd8
comment:20 Changed 9 years ago by Stuart Campbell
Add 10usec default monitor rebinning. refs #2811
Changeset: b32282d9d598a3aaaf2170b9b743683e2d3821fd
comment:21 Changed 9 years ago by Stuart Campbell
Swapped positions of high angle elastic banks. refs #2811
The banks at 4 and 10 o'clock (when looking back towards the moderator) are now swapped.
Changeset: 502a9937607aa27cf7521cf68854e1122a63d2c0
comment:22 Changed 9 years ago by Stuart Campbell
refs #2811. rotated 90 deg elastic banks.
The tubes on the high angle (90 deg) elastic detectors were facing the wrong way. i.e. +z --> -z
Changeset: b1702b97e662fb1b08fb77c8062061568959bedc
comment:23 Changed 9 years ago by Stuart Campbell
refs #2811. Updated valid-from date.
Changeset: 19f371370200c8caab1943e67d377de9869b6ba6
comment:24 Changed 8 years ago by Stuart Campbell
- Status changed from accepted to verify
- Resolution set to fixed
Current version is in use on the beam line and Uli & Malcolm seem happy with it for now.
comment:25 Changed 8 years ago by Michael Reuter
- Status changed from verify to verifying
- Tester set to Michael Reuter
comment:26 Changed 8 years ago by Michael Reuter
- Status changed from verifying to closed
Yes, this looks good.
comment:27 Changed 5 years ago by Stuart Campbell
This ticket has been transferred to github issue 3658
Bulk move of tickets at the end of iteration 28