Ticket #3270 (closed: fixed)
EQSANS: beam center is at the wrong position
Reported by: | Mathieu Doucet | Owned by: | Mathieu Doucet |
---|---|---|---|
Priority: | major | Milestone: | Iteration 29 |
Component: | Mantid | Keywords: | |
Cc: | Blocked By: | ||
Blocking: | Tester: | Martyn Gigg |
Description
The pixel (0,0) is at the wrong position (should be the lower right quadrant). The default center is not exactly the center of the detector, which needs to be corrected for.
Change History
comment:2 Changed 9 years ago by Mathieu Doucet
- Status changed from accepted to verify
- Resolution set to fixed
comment:4 Changed 9 years ago by Martyn Gigg
- Status changed from verify to reopened
- Resolution fixed deleted
This change has broken the EQSANS system test. It may just need the reference result updating?
comment:5 Changed 9 years ago by Mathieu Doucet
- Status changed from reopened to verify
- Resolution set to fixed
comment:6 Changed 9 years ago by Steve Williams
- Status changed from verify to verifying
- Tester set to Steve Williams
comment:7 Changed 9 years ago by Steve Williams
- Status changed from verifying to verify
- Tester Steve Williams deleted
Someone else please test this I have to leave for the day
comment:8 Changed 9 years ago by Martyn Gigg
- Status changed from verify to verifying
- Tester set to Martyn Gigg
comment:9 Changed 9 years ago by Martyn Gigg
- Status changed from verifying to closed
Mathieu is happy that the new reference result is correct and the detector seems to be at the correct coordinates after the MoveInstrumentComponent call.
comment:10 Changed 5 years ago by Stuart Campbell
This ticket has been transferred to github issue 4117
Note: See
TracTickets for help on using