Ticket #3673 (closed: fixed)

Opened 9 years ago

Last modified 5 years ago

ConvertUnits to TOF output differs using True/False PreserveEvents output from DiffractionFocussing

Reported by: Vickie Lynch Owned by: Vickie Lynch
Priority: major Milestone: Iteration 30
Component: Mantid Keywords:
Cc: Blocked By:
Blocking: Tester: Russell Taylor

Description

Event and histogram output from DiffractionFocussing should have the same detectorIDs for workspace indices. This seems to be related to masked detector pixels being included in the detectorIDs if PreserveEvents is false and excluded if PreserveEvents is true.

Change History

comment:1 Changed 9 years ago by Vickie Lynch

In [14427]:

Refs #3673 Detector IDs of masked pixels are not included when diffraction focussing histograms

comment:2 Changed 9 years ago by Vickie Lynch

  • Status changed from new to accepted

comment:3 Changed 9 years ago by Vickie Lynch

  • Status changed from accepted to verify
  • Resolution set to fixed

comment:4 Changed 9 years ago by Robert Whitley

  • Status changed from verify to verifying
  • Tester set to Robert Whitley

comment:5 Changed 9 years ago by Robert Whitley

  • Status changed from verifying to verify
  • Tester Robert Whitley deleted

comment:6 Changed 9 years ago by Russell Taylor

  • Status changed from verify to verifying
  • Tester set to Russell Taylor

comment:7 Changed 9 years ago by Russell Taylor

In [14837]:

Needed to add skipping of masked detectors to single group part of execEvent as well. Re #3673.

comment:8 Changed 9 years ago by Russell Taylor

  • Status changed from verifying to closed

Things look good after the last change. I've created a ticket (#3801) for myself just to look over this algorithm after the release to see if everything looks as it should.

comment:9 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 4520

Note: See TracTickets for help on using tickets.