Ticket #8876 (closed: fixed)
Mantid "show data" option incorrectly colours spectra as monitors
Reported by: | Samuel Jackson | Owned by: | Samuel Jackson |
---|---|---|---|
Priority: | major | Milestone: | Release 3.1 |
Component: | Framework | Keywords: | |
Cc: | Blocked By: | ||
Blocking: | Tester: | Roman Tolchenov |
Description
To reproduce:
- Open up any raw file
- Right click > Show Data
- Choose a lower range offset that excludes the monitors
- Observe that the first n spectra are coloured when they shouldn't be
Change History
comment:2 Changed 7 years ago by Samuel Jackson
Refs #8876 Correct spelling of method name.
Changeset: cde7d2f340a9b612ce3272f219cfd5bf13ed0f36
comment:3 Changed 7 years ago by Samuel Jackson
To Tester:
Check you can reproduce from the ticket description. Then check these changes fix it.
comment:4 Changed 7 years ago by Samuel Jackson
- Status changed from inprogress to verify
- Resolution set to fixed
comment:5 Changed 7 years ago by Roman Tolchenov
- Status changed from verify to verifying
- Tester set to Roman Tolchenov
comment:6 Changed 7 years ago by Roman Tolchenov
- Status changed from verifying to closed
Merge remote-tracking branch 'origin/bugfix/8876_mantid_matrix_offset'
Full changeset: c20f1d8967877628e61f869733f9cfba1d475c7b
Note: See
TracTickets for help on using
tickets.
Refs #8876 Apply the correct offset from monitor colouring.
Changeset: bd56466b4cc0679f2cb15d2fa432aeda8bd70b5e