SetSampleMaterial improvements

Reported by: Peter Peterson Owned by: Peter Peterson
Priority: major Milestone: Release 2.6
Component: Framework Keywords:
Cc: choffmann@…, wangx@… Blocked By: #7285
Blocking: Tester: Alex Buts

Description (last modified by Peter Peterson) (diff)

Chatted with Christina a Xiaoping today and many things were pointed out concerning SetSampleMaterial and some related algorithms.

  1. SetSampleMaterial should print units on the values being set
  2. SetSampleMaterial should work on a peaks workspace
  3. SetSampleMaterial should get the unit cell volume from the lattice if it is already attached to the workspace
  4. Clarify language concerning units of SampleNumberDensity
  5. Modify gui for SetSampleMaterial and help so it is clearer which parameters override which
  6. The logging of values should not abbreviate "Cross Section" as "X Section" as some people interpret it to mean the values for x-rays
  7. The scattering cross section does not appear to generate the correct value for "K1-C6-O6". Verify the value and fix the bug.
  8. Setting the chemical formula from C to C60 should do the same thing, currently C60 doesn't work.

Change History

comment:1 Changed 7 years ago by Peter Peterson

  • Description modified (diff)

comment:2 Changed 7 years ago by Peter Peterson

  • Status changed from new to accepted
  • Cc choffmann@…, wangx@… added

comment:3 Changed 7 years ago by Peter Peterson

  • Blocked By 7285 added

comment:4 Changed 7 years ago by Peter Peterson

  • Description modified (diff)

comment:5 Changed 7 years ago by Peter Peterson

Point 8: the C60 thing is an issue with Material that has its own ticket now #7299.

comment:6 Changed 7 years ago by Peter Peterson

Re #7279. Centralized logging the material information.

Changeset: eda7e5895614507554517ed320a809df1d443635

comment:7 Changed 7 years ago by Peter Peterson

Re #7279. Fixing up the whitespace.

Changeset: f95f875d939eb288ee2e7c196bebfc6d600e63c5

comment:8 Changed 7 years ago by Peter Peterson

Re #7279. Fixed bug in calculations and made rho override correct.

Changeset: 31bc4636e71885d83fef01c2966c2a2389fe8a2a

comment:9 Changed 7 years ago by Peter Peterson

Re #7279. Improved documentation of SampleNumberDensity parameter.

Changeset: 82a4938f6ffc4c8601128b7e670a673b2a5a2deb

comment:10 Changed 7 years ago by Peter Peterson

Re #7279. Modified print to not show a_number for isotopic averages.

Changeset: 3693f3c9d6f5171ce7b982c1465609babfd4ac56

comment:11 Changed 7 years ago by Peter Peterson

Re #7279. Make calculating rho more rhobust.

Also added enabling and disabling parameters to make it clearer to the user what is going on.

Changeset: abf3b50a788649320778f2409d8b477c38c44eee

comment:12 Changed 7 years ago by Peter Peterson

Re #7279. Added some math operators to NeutronAtom.

They are there to make SetSampleMaterial more readable.

Changeset: 6746f689e66ac87a9197fd95bba02995083d023f

comment:13 Changed 7 years ago by Peter Peterson

Re #7279. Using new math operators for NeutronAtom.

Changeset: ea310d3f5d5380ef70189cca596f5e576d0ddc05

comment:14 Changed 7 years ago by Peter Peterson

Re #7279. Fairly major reworking of SetSampleMaterial.

  • Collapsed the if/else try/catch tree
  • Factored out some code into a separate function
  • Adding more verification and guidance of input parameters.

Changeset: 41bcb8c52fef06fc0af23f64725b65a953739425

comment:15 Changed 7 years ago by Peter Peterson

Re #7279. Moved implementation from header into source file.

Changeset: 3d0b57313e5756689e1df493054df717ca01ada6

comment:16 Changed 7 years ago by Peter Peterson

Re #7279. Modifying unit test results to reflect bugfix.

Changeset: abc32dc8f5604972b83149cd0b6d17823b770f19

comment:17 Changed 7 years ago by Peter Peterson

  • Status changed from accepted to verify
  • Resolution set to fixed

This is on feature/7279_SetSampleMaterial_improvements

To test just try out all of the things in the ticket description.

comment:18 Changed 7 years ago by Peter Peterson

  • Status changed from verify to reopened
  • Resolution fixed deleted

comment:19 Changed 7 years ago by Peter Peterson

Re #7279. Fixed unit test that originally worked on my machine.

Changeset: bf7dedf8fe18fb368d7144c3f449e0c1d6907d3f

comment:20 Changed 7 years ago by Peter Peterson

Re #7279. Modified test values to reflect total scattering changes.

Martyn said it was the right thing to do and I always listen to him.

Changeset: 573bfdc5d1d79a307ccce29e36bfdd6d4662d9c5

comment:21 Changed 7 years ago by Peter Peterson

  • Status changed from reopened to accepted

comment:22 Changed 7 years ago by Peter Peterson

  • Status changed from accepted to verify
  • Resolution set to fixed

Same branch and testing notes as before, except the build servers now give it a thumbs up.

comment:23 Changed 7 years ago by Alex Buts

  • Status changed from verify to verifying
  • Tester set to Alex Buts

comment:24 Changed 7 years ago by Alex Buts

  • Status changed from verifying to closed

Big job and algorithm seems mainly works and certainly look better.

For some reasons does not like Fe60 isotope as attempting to set oxide as (Fe60)2-O3 generates strange cross-section values. Fe56 works fine. Can not identify importance of the former, so pass on main purpose.

comment:25 Changed 7 years ago by Nick Draper

  • Component changed from Mantid to Framework

comment:26 Changed 5 years ago by Stuart Campbell

This ticket has been transferred to github issue 8125

Note: See TracTickets for help on using tickets.